2015 Chevrolet City Express
Mileage
100,523
Service Date
7/30/2026
Services Performed
- Found A/C system low on refrigerant. Removed refrigerant and only .44lb came out. Requires .88lb. Found only one very small leak at suction charge port seal. Replaced seal. Added NITROGEN to 120psi and let it soak for an hour, no leak down. Pulled vacuum and it held for an hour. Evacuate system again and recharge to .88lb and it blows cold. THIS IS DIAGNOSE ONLY CHARGE. After it was charged, test drove and then found the system turns off and on often. Found evap temp sensor turning off A/C because it is freezing up. Found evaporator completely covered with leaves and hay. Cleaned evap. Now it stays on.
- AIR CONDITIONING SYSTEM – Complete Charge – [Includes: Air Conditioning system recover, evacuate and recharge.]
- CHarge port seal replaced
- Washed A/C evaporator
William Clay G. gave our service a 5 star review on 8/1/2026